2010 Ford Cutaway

  • 2010 Ford Cutaway

    Ford Cutaway
    Mileage
    296,369
    Service Date
    12/1/2022
    Services Performed
    • FOUND: fuel gauge is currently indicating that there is 20% fuel in the tank. There are no circuit code set indicating a failure of the sending unit. Commanded the fuel gauge to the full and empty ranges with the scan tool and found that it moves to each. If the gauge is not accurate to the actual amount of fuel in the tank, it is likely that the sending unit is defective and miscalibrated. The fuel tank has collapsed most likely due to a buildup of excess vacuum in the tank. The fuel tank has a complete unit will need to be replaced including all the valves that are integral to the fuel tank for fuel and air flow. The fuel pump and fuel sending unit should also be replaced. The evaporative system components will also need to be replaced including the evaporative emissions canister, the purge solenoid, the vent solenoid, and the fuel cap. After replacement all of the EVAP Vapor lines will need to be blown out to make sure that there is no restriction to Vapor flow.
    • GASOLINE ADDED 1.798 GALS 11/21/2022
    • REMOVE & REPLACE FUEL TANK
    • BLOW OUT VENT LINES
    • REMOVE & REPLACE CARBON CANISTER
    • REMOVE & REPLACE PURGE VALVE {DOGHOUSE REMOVAL}
     